Product Family: MICROMASTER 4

The Siemens 6SE6400-1PB00-0AA0 MICROMASTER 4 PROFIBUS Module is a PROFIBUS DP communication module for Siemens MICROMASTER 4 variable frequency drives. It connects compatible MICROMASTER 420, MICROMASTER 430, MICROMASTER 440, and MM4 FX and GX drive variants to an industrial PROFIBUS network. The module provides an RS-485 PROFIBUS DP interface through a 9-pin Sub-D female connector and operates as a fieldbus slave.

The module supports PROFIBUS DP-V0 and DP-V1, PPO types 1 to 5, and communication speeds from 9.6 kbit/s to 12 Mbit/s. It uses a 24 V DC external supply and provides an electrically isolated 5 V DC supply output with a current rating of 100 mA. When replacing a module, configure the PROFIBUS station address through drive parameter P0918; the module parameters and address are stored in the host drive memory. A BOP or AOP operator panel, Siemens DriveMonitor, or STARTER software can be used for replacement setup. MM4 FX and GX frame sizes require the Siemens 6GK1500-0EA02 bus connection adapter.

During troubleshooting, check the BUSF indicator for a PROFIBUS bus failure or communication interruption, then check the PROFIBUS network connection and station address. The address range is 1 to 126 through parameter P0918. Check firmware compatibility before installing the replacement on a MICROMASTER 420, 430, or 440 drive. As a discontinued MICROMASTER 4 product, this module is relevant to repair and spare-part programs for legacy PROFIBUS-based drive systems.

Technical Specifications

ManufacturerSiemens
Part number6SE6400-1PB00-0AA0
Model/typeMICROMASTER 4 PROFIBUS Module
Component typePROFIBUS DP communication module
Product familyMICROMASTER 4
Communication protocolPROFIBUS DP-V0 and DP-V1
Physical interfaceRS-485 PROFIBUS DP
Connector9-pin Sub-D female
PROFIBUS device roleFieldbus slave
Supported PPO typesPPO types 1 to 5
Communication speed9.6 kbit/s to 12 Mbit/s
External supply voltage24 V DC
Current rating100 mA
Isolated supply output5 V DC
Compatible drive seriesMICROMASTER 420, MICROMASTER 430, MICROMASTER 440, MM4 FX and GX variants
Required connector for FX/GX frame sizesSiemens 6GK1500-0EA02 bus connection adapter
PROFIBUS station address range1 to 126 via drive parameter P0918
Product lifecycle statusDiscontinued; legacy product family

Programming and Configuration

Replacement configuration is performed through the MICROMASTER drive. Set the PROFIBUS station address with drive parameter P0918; the configurable address range is 1 to 126. Module parameters and the address are stored in the host inverter's non-volatile memory.

A MICROMASTER BOP or AOP operator panel can be used for configuration and verification. Siemens DriveMonitor and STARTER software also support drive and communication setup, allowing the replacement module to be aligned with the existing drive configuration.

Communication and System Integration

The 6SE6400-1PB00-0AA0 connects to PROFIBUS DP networks through an integrated RS-485 interface and a 9-pin Sub-D female connector. It supports PROFIBUS DP-V0 and DP-V1 operation, functions as a fieldbus slave, and supports PPO types 1 to 5.

Communication speeds range from 9.6 kbit/s to 12 Mbit/s. The module uses a 24 V DC external supply and provides an electrically isolated 5 V DC supply output rated at 100 mA. For MM4 FX and GX frame sizes, use the Siemens 6GK1500-0EA02 bus connection adapter.

Diagnostics and Status Indication

The BUSF status indicator identifies a PROFIBUS bus failure or communication interruption. Use this indication together with the drive configuration to determine whether the issue is related to the PROFIBUS connection or station addressing.

Check the PROFIBUS network connection and confirm the station address through parameter P0918. A BOP or AOP operator panel, Siemens DriveMonitor, or STARTER software can be used for configuration and communication checks.

Status LED Indicators

LEDColor/StatusMeaning
BUSFBus failure or communication interruption on the PROFIBUS network

Replacement and Spare Part Considerations

Match the replacement to the exact Siemens part number 6SE6400-1PB00-0AA0 and to the installed MICROMASTER 420, 430, 440, MM4 FX, or GX drive variant. For FX and GX frame sizes, the Siemens 6GK1500-0EA02 bus connection adapter is required.

Before returning the drive to service, configure the PROFIBUS station address with parameter P0918 and align the module with the existing network configuration. Use a BOP or AOP operator panel, DriveMonitor, or STARTER software for setup, then check the BUSF indication and PROFIBUS connection.

This is a discontinued MICROMASTER 4 product intended for legacy equipment support. Check firmware compatibility before installation, particularly when fitting the module to MICROMASTER 420, 430, or 440 drives.

Frequently Asked Questions

Which drives are compatible with the Siemens 6SE6400-1PB00-0AA0?

The module is intended for Siemens MICROMASTER 420, MICROMASTER 430, MICROMASTER 440, and compatible MM4 FX and GX drive variants.

What PROFIBUS interface does this module use?

It provides an RS-485 PROFIBUS DP interface with a 9-pin Sub-D female connector and operates as a fieldbus slave.

What PROFIBUS speeds are supported?

The supported communication range is 9.6 kbit/s to 12 Mbit/s. The module supports PROFIBUS DP-V0, DP-V1, and PPO types 1 to 5.

How is the PROFIBUS station address configured after replacement?

Configure the station address through MICROMASTER drive parameter P0918. The supported address range is 1 to 126, and the setting is stored in the host drive memory.

Which tools can be used to commission the replacement module?

A MICROMASTER BOP or AOP operator panel, Siemens DriveMonitor, or STARTER software can be used for configuration and communication setup.

What does the BUSF indicator mean?

BUSF indicates a PROFIBUS bus failure or communication interruption. Check the PROFIBUS network connection and the station address configured through P0918.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Siemens.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.