Allen-Bradley 1756-RIO ControlLogix Remote I/O Module

New 
On request
Refurbished   
On request
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: ControlLogix

The Allen-Bradley 1756-RIO is a ControlLogix Remote I/O Scanner/Adapter Module and communication module for connecting a ControlLogix chassis with established Allen-Bradley Remote I/O networks. It operates as either a scanner or an adapter and occupies one ControlLogix chassis slot. The module supports digital, analog, block-transfer and specialty data, with the RIO network connected through a 3-pin removable terminal block.

A replacement 1756-RIO must match the existing ControlLogix and Remote I/O architecture, including the selected operating mode, network baud rate and rack configuration. The module supports 57.6, 115.2 and 230.4 Kbps, up to 32 physical racks, up to 32 logical rack connections per channel, 10 scheduled I/O connections and 16 block transfers. Configuration is stored non-volatilely in the Logix controller project and transferred to the module through the ControlLogix backplane using RSLogix 5000 or Studio 5000 Logix Designer, so a spare requires a controller project download and commissioning before operation.

For troubleshooting, the front-panel OK and RIO Channel indicators provide module and network status information, while RSLogix 5000 or Studio 5000 Logix Designer provides module diagnostics through the I/O tree, status and fault tags. Check that the replacement is seated in the correct ControlLogix chassis installation, that the RIO trunk uses the same baud rate across all nodes, and that line termination is correct. When the 1756-RIO is used as an adapter, the chassis must include a ControlLogix controller. The module is discontinued, making exact part-number matching and configuration recovery important when preparing a spare or repair exchange.

Technical Specifications

ManufacturerAllen-Bradley
Part number1756-RIO
Model/typeControlLogix Remote I/O Scanner/Adapter Module
Component typeCommunication module
Product familyControlLogix
Remote I/O network interfaceAllen-Bradley Remote I/O (RIO)
Operating modeScanner or adapter
RIO connector3-pin removable terminal block
Supported baud rates57.6, 115.2, 230.4 Kbps
Maximum physical racks32 racks
Maximum logical rack connections per channel32 connections
Maximum scheduled I/O connections10
Maximum block transfers16
Supported data typesDigital, analog, block-transfer, and specialty data
Chassis slot width1 slot
Backplane current draw at 5.1 V DC450 mA
Backplane current draw at 24 V DC5 mA
Power dissipation2.5 W
Thermal dissipation8.5 BTU/h
Configuration storageNon-volatile configuration stored in the Logix controller project
Lifecycle statusDiscontinued

Programming and Configuration

The 1756-RIO is configured through RSLogix 5000 or Studio 5000 Logix Designer. The Logix controller project contains the non-volatile configuration, which is downloaded to the module through the ControlLogix backplane.

When commissioning a spare, transfer the applicable controller project to the replacement module and confirm the configured scanner or adapter mode, RIO network baud rate and rack connections. The configured network must correspond with the established Remote I/O architecture before the module is returned to service.

Communication and System Integration

The 1756-RIO connects ControlLogix systems to Allen-Bradley Remote I/O networks through a 3-pin removable terminal block. It can operate as a Remote I/O scanner or adapter, supporting digital, analog, block-transfer and specialty data.

The module supports 57.6, 115.2 and 230.4 Kbps baud rates. Scanner operation supports up to 32 physical racks and up to 32 logical rack connections per channel, with a maximum of 10 scheduled I/O connections and 16 block transfers. All nodes on the RIO trunk must use the same baud rate and proper line termination.

Diagnostics and Status Indication

Front-panel OK and RIO Channel status indicators provide local visibility of the module operational state and Remote I/O network activity.

For software diagnostics, use RSLogix 5000 or Studio 5000 Logix Designer. The Logix Designer I/O tree provides module status and fault tags for troubleshooting the 1756-RIO installation.

Status LED Indicators

LEDColor/StatusMeaning
OKIndicates module operational state and health
RIO ChannelIndicates Remote I/O channel communication status and network link activity

Replacement and Spare Part Considerations

For a replacement, verify the exact Allen-Bradley 1756-RIO part number, the ControlLogix chassis installation, the selected scanner or adapter mode and the Remote I/O network baud rate. The 3-pin removable terminal block and established RIO trunk configuration must also correspond with the installation.

The spare requires configuration transfer from the Logix controller project through the ControlLogix backplane. Before returning the system to operation, confirm the rack configuration, scheduled I/O connections, block-transfer requirements and network line termination.

The 1756-RIO is discontinued. Exact part-number matching, project availability and compatibility with the existing Remote I/O architecture are therefore important when selecting a repair or exchange unit.

Frequently Asked Questions

What is the Allen-Bradley 1756-RIO used for?

The 1756-RIO connects a ControlLogix platform with Allen-Bradley Remote I/O networks and can operate as either a Remote I/O scanner or adapter.

Which baud rates does the 1756-RIO support?

The module supports 57.6, 115.2 and 230.4 Kbps. All nodes on the RIO trunk must use the same baud rate.

How many racks can the 1756-RIO support?

The 1756-RIO supports up to 32 physical racks and up to 32 logical rack connections per channel. It also supports up to 10 scheduled I/O connections and 16 block transfers.

Which software is used to configure and diagnose the 1756-RIO?

RSLogix 5000 or Studio 5000 Logix Designer is used for configuration, controller project downloads and diagnostics. The Logix Designer I/O tree provides module status and fault tags.

What should be checked when replacing a 1756-RIO?

Check the exact part number, ControlLogix chassis installation, scanner or adapter mode, RIO baud rate, rack configuration, 3-pin terminal block connection and line termination. Transfer the applicable Logix controller project before commissioning the spare.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Allen-Bradley.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.