Siemens 6ES7416-2XK02-0AB0 SIMATIC S7-400 CPU 416-2 PLC

Het item werd toegevoegd aan uw offerteaanvraag
Product Information
The Siemens 6ES7416-2XK02-0AB0 is a SIMATIC S7-400 CPU 416-2 central processing unit for modular industrial automation and process-control systems. It operates in a central rack with an S7-400 backplane bus and provides 1.6 MB of integrated work memory, divided into 800 kB of program memory and 800 kB of data memory. The PLC CPU is designed for demanding control programs, large distributed I/O systems and central controller configurations with up to 4 CPUs.
A replacement CPU is commissioned through Siemens STEP 7 and SIMATIC Manager using the existing project, hardware configuration and network settings. The unit has two galvanically isolated RS-485 interfaces with 9-pin Sub-D connectors: Interface 1 supports MPI and PROFIBUS DP, while Interface 2 supports PROFIBUS DP. Program and load memory can be transferred through an S7-400 RAM Memory Card or FLASH FEPROM Memory Card; the load memory can be expanded up to 64 MB with either memory-card type. A spare is therefore normally subject to project transfer, memory-card transfer or configuration work before returning the machine to service.
The CPU indicates its operating and fault state through the RUN, STOP, INTF, EXTF, BUS1FL and BUS2FL indicators. STEP 7 provides hardware configuration, commissioning, programming and diagnostic-buffer access, including up to 3200 programmable diagnostic entries with a default capacity of 120 entries. For troubleshooting, check the CPU mode, the STEP 7 diagnostic buffer, the MPI or PROFIBUS DP configuration and node addressing, and the affected expansion rack, bus slave or signal module. An INTF condition can indicate an internal CPU hardware failure or internal system error and may require CPU service or replacement if it does not clear.
Technical Specifications
| Manufacturer | Siemens |
| Part number | 6ES7416-2XK02-0AB0 |
| Model/type | SIMATIC S7-400 CPU 416-2 |
| Component type | PLC central processing unit |
| Product family | SIMATIC S7-400 |
| System architecture | Modular SIMATIC S7-400 automation system with central rack backplane bus |
| Integrated work memory | 1.6 MB |
| Program memory | 800 kB |
| Data memory | 800 kB |
| Integrated RAM load memory | 256 kB |
| Maximum RAM load memory expansion | 64 MB |
| Maximum FLASH FEPROM load memory expansion | 64 MB |
| Bit operation execution time | 0.08 µs |
| Word operation execution time | 0.08 µs |
| Floating-point operation execution time | 0.48 µs |
| Maximum digital inputs address space | 131072 channels |
| Maximum digital outputs address space | 131072 channels |
| Maximum analog inputs address space | 8192 channels |
| Maximum analog outputs address space | 8192 channels |
| S7 counters | 512 counters |
| S7 timers | 512 timers |
| Maximum data blocks | 4095; DB 0 reserved; maximum block size 64 KB |
| Maximum function blocks | 2048; maximum block size 64 KB |
| Maximum functions | 2048; maximum block size 64 KB |
| Interface 1 | MPI and PROFIBUS DP via galvanically isolated RS-485, 9-pin Sub-D, up to 12 Mbit/s |
| Interface 2 | PROFIBUS DP via galvanically isolated RS-485, 9-pin Sub-D, up to 12 Mbit/s |
| Interface 1 MPI connections | 44 connections |
| Interface 1 PROFIBUS DP connections | 32 slaves |
| Interface 2 PROFIBUS DP connections | 125 slaves |
| Supported communication services | MPI, PROFIBUS DP master, PROFIBUS DP slave, S7 communication, PG/OP communication, global data communication |
| Central controller multicomputing | Up to 4 CPUs |
| Backplane bus current at 5 V DC, typical | 1.5 A |
| Backplane bus current at 5 V DC, maximum | 1.6 A |
| Backplane bus current at 24 V DC, maximum | 300 mA |
| Power loss | 7.5 W |
Programming and Configuration
The Siemens CPU 416-2 is programmed, configured and commissioned with STEP 7 and SIMATIC Manager. The engineering environment is used for the S7-400 hardware configuration, program download, network setup and diagnostic functions. An existing replacement project should include the CPU configuration, connected modules and MPI or PROFIBUS DP settings.
The CPU provides 256 kB of integrated RAM load memory and accepts S7-400 RAM Memory Cards or FLASH FEPROM Memory Cards for load-memory expansion up to 64 MB. A replacement can be prepared by downloading the STEP 7 project or transferring the required program through the applicable memory card. RAM operation depends on the S7-400 power supply backup battery, while FLASH FEPROM provides non-volatile storage.
Communication and System Integration
Interface 1 is a galvanically isolated RS-485 interface on a 9-pin Sub-D connector and supports MPI as well as PROFIBUS DP master or slave operation at up to 12 Mbit/s. Interface 1 supports up to 44 MPI connections and up to 32 PROFIBUS DP slaves.
Interface 2 is a second galvanically isolated RS-485 interface with a 9-pin Sub-D connector for PROFIBUS DP master or slave communication at up to 12 Mbit/s. It supports up to 125 PROFIBUS DP slaves. Communication services include S7 communication, PG/OP communication and global data communication via MPI.
Diagnostics and Status Indication
STEP 7 provides access to the CPU diagnostic buffer for system and CPU fault entries. The diagnostic buffer supports up to 3200 programmable entries, with a default capacity of 120 entries. STEP 7 also supports hardware configuration, programming, commissioning and diagnostics for the S7-400 system.
The status indicators identify the CPU operating mode, internal and external faults, and communication faults on the two interfaces. BUS1FL and BUS2FL should be checked together with MPI or PROFIBUS DP configuration, node addressing and bus connections. EXTF can point to an expansion rack failure, bus slave failure or signal module error.
Status LED Indicators
| LED | Color/Status | Meaning |
|---|---|---|
| INTF | Internal Fault: Indicates an internal CPU hardware failure or internal system error. A severe condition may require CPU service or replacement if it does not clear. | |
| EXTF | External Fault: Indicates an external system fault, such as an expansion rack failure, bus slave failure, or signal module error. | |
| RUN | CPU is in RUN execution mode. | |
| STOP | CPU is in STOP mode. | |
| BUS1FL | Bus fault on Interface 1, the MPI/PROFIBUS DP interface, indicating a communication failure or configuration mismatch. | |
| BUS2FL | Bus fault on Interface 2, the PROFIBUS DP interface, indicating a communication failure or bus disruption. |
Replacement and Spare Part Considerations
The exact part number 6ES7416-2XK02-0AB0 and model SIMATIC S7-400 CPU 416-2 should match the failed unit before replacement. Confirm the central rack and backplane bus arrangement, the required memory-card type and the use of MPI or PROFIBUS DP interfaces. Interface 1 and Interface 2 have different communication roles, so the existing network connections and node addressing must be preserved.
This Siemens CPU is discontinued and is relevant for legacy S7-400 repair and replacement work. A spare normally requires the STEP 7 project, hardware configuration, program transfer or memory-card transfer, and commissioning of the connected networks. If the INTF indication remains active because of an internal CPU hardware failure or internal system error, CPU service or a tested replacement may be required.
Frequently Asked Questions
What is the exact replacement part number for the Siemens CPU 416-2?
The exact part number is 6ES7416-2XK02-0AB0. The model/type is SIMATIC S7-400 CPU 416-2.
Which software is used to program and commission this S7-400 CPU?
Siemens STEP 7 and SIMATIC Manager are used for hardware configuration, programming, commissioning, project download and diagnostics.
Which communication interfaces are built into the CPU 416-2?
Interface 1 provides galvanically isolated RS-485 communication through a 9-pin Sub-D connector and supports MPI and PROFIBUS DP. Interface 2 provides galvanically isolated RS-485 PROFIBUS DP communication through a 9-pin Sub-D connector.
How many PROFIBUS DP slaves can Interface 2 support?
Interface 2 supports up to 125 PROFIBUS DP slaves.
Can the program be transferred to a replacement CPU using a memory card?
Yes. The CPU supports S7-400 RAM Memory Cards and FLASH FEPROM Memory Cards. Load memory can be expanded up to 64 MB with either memory-card type.
What should be checked when BUS1FL or BUS2FL is active?
Check the relevant MPI or PROFIBUS DP network configuration, node addressing and bus connection. BUS1FL concerns Interface 1, while BUS2FL concerns Interface 2.
Take advantage of our exchange formula
A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.
Play it safe with our warranty conditions
Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.
Data backup and recovery
Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.
Specific firmware and hardware versions
If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.