Keithley 6430 Sub-Femtoamp Remote SourceMeter SMU

New 
On request
Refurbished   
On request
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 6400 Series SourceMeter

The Keithley 6430 Sub-Femtoamp Remote SourceMeter is a single-channel Source Measure Unit (SMU) that combines precision sourcing and measurement for ultra-low-current characterization. It operates in four quadrants for both source and sink testing, with output capability up to ±200 V, ±100 mA and 2.2 W. Current resolution reaches 10 aA, typical peak-to-peak current noise is 0.4 fA, and measurement resolution reaches up to 6.5 digits. As part of the Keithley 6400 Series SourceMeter family, the 6430 is used for semiconductor leakage testing, nanotechnology device characterization, photodiode and photonic component measurement, and low-noise electronic or materials research.

The remote preamplifier architecture places sensitive amplification circuitry close to the device under test, helping reduce cable capacitance and microphonic noise. A Keithley 6430 Remote PreAmp is connected through a specialized 2 m bidirectional cable, with 3-slot triaxial cabling and guarded connections used for low-noise measurements. The instrument provides IEEE-488/GPIB control and programmable digital I/O for automated component characterization and handler triggering. When preparing a replacement or spare, the preamplifier, interconnecting cable, triaxial cabling and guarded test connections must match the intended 6430 measurement setup.

For replacement commissioning, check the complete remote measurement chain before applying the unit: the Keithley 6430 Remote PreAmp, specialized 2 m cable, 3-slot triaxial connections, guarded test connections and IEEE-488/GPIB control path. The 6430 supports acquisition rates up to 2000 readings per second, an internal buffer for up to 5000 readings and a source memory list of 100 points. These functions support repeatable automated testing, while compatibility of the connected preamplifier and low-noise cabling remains central to achieving the expected ultra-low-current measurement performance.

Technical Specifications

ManufacturerKeithley
Part number6430
Model/typeSub-Femtoamp Remote SourceMeter
Component typeSource Measure Unit (SMU)
Product family6400 Series SourceMeter
Measurement channels1 channel
Maximum source voltage±200 V DC
Maximum source current±100 mA DC
Maximum output power2.2 W
Current resolution10 aA
Typical peak-to-peak current noise0.4 fA p-p
Voltage measurement input resistance>10^16 Ω
Maximum common-mode voltage±42 V DC
Common-mode isolation resistance>10^9 Ω
Common-mode isolation capacitance<1000 pF
Measurement resolutionUp to 6.5 digits
Maximum reading rate2000 readings/s
Internal reading buffer5000 readings
Source memory list100 points
Control interfaceIEEE-488 / GPIB
Digital I/OProgrammable digital I/O for handler triggering and component test control
Remote preamplifier connectionExternal bidirectional preamplifier connected by a 2 m cable
Low-noise connection3-slot triaxial cabling and guarded connections
Lifecycle statusActive

Communication and System Integration

The Keithley 6430 uses an IEEE-488/GPIB control interface for integration into automated test systems. Programmable digital I/O provides handler triggering and component test control, supporting automated component characterization and repeatable measurement sequences.

The measurement connection uses a Keithley 6430 Remote PreAmp linked by a specialized 2 m bidirectional cable. For low-noise operation, the setup uses 3-slot triaxial cabling and guarded test connections. These interfaces and connection elements should be matched when integrating or replacing a 6430 in an existing test system.

Replacement and Spare Part Considerations

A replacement Keithley 6430 should be checked against the exact part number, the 6400 Series SourceMeter family and the Sub-Femtoamp Remote SourceMeter type. The complete measurement arrangement also includes the Keithley 6430 Remote PreAmp, its specialized 2 m interconnecting cable, 3-slot triaxial cabling and guarded connections.

Before commissioning a spare, verify the IEEE-488/GPIB control path and programmable digital I/O connections used for handler triggering and component test control. Confirming the preamplifier and low-noise connection chain is important because the remote architecture is designed to place sensitive circuitry close to the device under test and to reduce cable capacitance and microphonic noise.

Frequently Asked Questions

What is the Keithley 6430?

The Keithley 6430 is a single-channel Sub-Femtoamp Remote SourceMeter and Source Measure Unit (SMU) in the 6400 Series SourceMeter family.

What current resolution does the Keithley 6430 provide?

The Keithley 6430 provides current resolution down to 10 aA, with typical peak-to-peak current noise of 0.4 fA when configured with the remote preamplifier.

What must be checked when replacing a Keithley 6430?

Check the 6430 part number and type, the Keithley 6430 Remote PreAmp, the specialized 2 m cable, 3-slot triaxial cabling, guarded test connections, IEEE-488/GPIB control and programmable digital I/O connections.

Which interfaces does the Keithley 6430 use for automated testing?

The Keithley 6430 uses IEEE-488/GPIB control and programmable digital I/O for automated component characterization, handler triggering and component test control.

What are the maximum source ratings of the Keithley 6430?

The Keithley 6430 supports up to ±200 V DC, ±100 mA DC and 2.2 W output power, with four-quadrant source and sink operation.

Related products

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Keithley.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.