UniOp ETOP312U301 eTOP312 12.1-Inch HMI Operator Panel

Het item werd toegevoegd aan uw offerteaanvraag
Product Information
The UniOp ETOP312U301, also identified as the eTOP312, is a 12.1-inch HMI operator interface from the eTOP Series 300. It combines an 800 x 600 SVGA TFT LCD color display with 64K colors and an analog resistive touchscreen for machine operation, process visualization, and operator data entry. The front panel has IP65 protection, while the rear enclosure is rated IP20. A 24 V DC supply powers the panel, which is designed for installation in a protected industrial control-panel environment.
Replacement commissioning depends on matching the installed project and communication setup. UniOP Designer 6.0 or higher is used to configure and program the eTOP312. Applications, firmware, and recipes can be transferred over the 10/100 Mbit/s RJ45 Ethernet interface or through the USB-A Host port using a USB flash drive. The PLC port and PC/printer interface support configurable RS-232, RS-485, or RS-422 communication, while optional TCM/SCM plug-in modules provide PROFIBUS-DP, CANopen, DeviceNet, or INTERBUS connectivity. Before putting a spare into service, match the project revision, network settings, serial configuration, and any required fieldbus module.
The eTOP312 stores applications, firmware, and recipes in 64 MB of non-volatile Flash memory. For troubleshooting and commissioning, UniOP Designer 6 runtime diagnostics can be used, and the panel can be placed in Manual Configuration Mode by powering it off, touching and holding the middle-left screen area, powering it on, and repeatedly tapping the middle-right area at approximately one-second intervals until Configuration Mode appears. The discontinued status of this model makes exact part-number matching and project recovery important for repair, retrofit, and exchange-unit work; ABC Industrial Parts can support spare preparation and configuration-transfer requirements.
Technical Specifications
| Manufacturer | UniOp |
| Part number | ETOP312U301 |
| Model/type | eTOP312 |
| Component type | HMI operator interface |
| Product family | eTOP Series 300 |
| Display size | 12.1 in |
| Display resolution | 800 x 600 pixels |
| Display type | TFT LCD |
| Display colors | 64K |
| Touchscreen type | Analog resistive |
| User memory | 64 MB Flash |
| Supply voltage | 24 V DC (+10% / -15%) |
| Rated current | 0.8 A at 24 V DC |
| Front panel protection | IP65 |
| Rear enclosure protection | IP20 |
| Ethernet interface | 10/100 Mbit/s, RJ45 |
| USB Host interface | USB-A |
| PLC serial interface | DB9; configurable RS-232, RS-485, or RS-422 |
| PC/printer interface | Configurable RS-232, RS-485, or RS-422 |
| Built-in network | UniNet Ethernet-based HMI networking |
| Optional fieldbus support | PROFIBUS-DP, CANopen, DeviceNet, and INTERBUS via TCM/SCM plug-in module |
| Engineering software | UniOP Designer 6.0 or higher |
| Product lifecycle status | Discontinued |
Programming and Configuration
UniOP Designer 6.0 or higher is used for eTOP312 application programming and configuration. The panel stores application projects, firmware, and recipes in 64 MB of non-volatile Flash memory.
Project transfer can be performed through the 10/100 Mbit/s RJ45 Ethernet interface or through the USB-A Host port with a USB flash drive. A replacement panel should receive the correct HMI project, firmware, and recipes before commissioning, with the installed network settings, serial-port mode, and optional TCM/SCM fieldbus module matched to the machine.
Communication and System Integration
The eTOP312 provides an RJ45 Ethernet interface supporting 10/100 Mbit/s communication, programming, data retrieval, and UniNet Ethernet-based HMI networking. A USB-A Host port supports transfer of applications, firmware, and recipes using a USB flash drive.
The DB9 PLC port and the separate PC/printer interface are configurable for RS-232, RS-485, or RS-422 communication. Optional TCM/SCM plug-in modules extend the panel with PROFIBUS-DP, CANopen, DeviceNet, or INTERBUS fieldbus connectivity, depending on the installed module.
Diagnostics and Status Indication
UniOP Designer 6 runtime diagnostics provides a diagnostic method for the eTOP312 during commissioning and service work. The panel also provides Manual Configuration Mode for checking or adjusting panel configuration when required.
To access Manual Configuration Mode, power off the panel, touch and hold the middle-left screen area, power on the panel, and repeatedly tap the middle-right area at approximately one-second intervals until Configuration Mode appears.
Replacement and Spare Part Considerations
The ETOP312U301 is a discontinued UniOp HMI operator panel intended for service, repair, retrofit, and replacement of installed eTOP312 systems. Confirm the exact part number, 12.1-inch display format, communication interfaces, serial-port configuration, and front-panel protection before selecting a spare.
A replacement is not complete until the machine-specific HMI project, firmware, recipes, network settings, and serial communication settings are transferred or restored. Where the installation uses PROFIBUS-DP, CANopen, DeviceNet, or INTERBUS, the required TCM/SCM plug-in module must also match the existing system. ABC Industrial Parts can support spare preparation and configuration-transfer work for installed units.
Frequently Asked Questions
What is the UniOp ETOP312U301?
The ETOP312U301 is the UniOp eTOP312, a 12.1-inch HMI operator interface from the eTOP Series 300 with an 800 x 600 TFT LCD, 64K colors, analog resistive touchscreen, Ethernet, USB Host, and configurable serial interfaces.
Which software is used to program the eTOP312?
UniOP Designer 6.0 or higher is used for eTOP312 programming and configuration.
How can an eTOP312 project be transferred to a replacement panel?
Applications, firmware, and recipes can be transferred over the 10/100 Mbit/s RJ45 Ethernet interface or through the USB-A Host port using a USB flash drive.
Which communication interfaces are available on the ETOP312U301?
The panel has 10/100 Mbit/s RJ45 Ethernet, a USB-A Host port, a DB9 PLC port configurable for RS-232, RS-485, or RS-422, and a separate PC/printer interface configurable for RS-232, RS-485, or RS-422. Optional TCM/SCM modules support PROFIBUS-DP, CANopen, DeviceNet, or INTERBUS.
How do I access Manual Configuration Mode?
Power off the panel, touch and hold the middle-left screen area, power on the panel, and repeatedly tap the middle-right area at approximately one-second intervals until Configuration Mode appears.
Take advantage of our exchange formula
A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.
Play it safe with our warranty conditions
Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.
Data backup and recovery
Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.
Specific firmware and hardware versions
If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.
Disclaimer:
We are not an authorised distributor of UniOp.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.