Product Information

Product Family: SIMATIC HMI

The Siemens 6AV6642-0EA01-3AX0 is a SIMATIC MP 177 6 Touch HMI multi panel for machine operation, process visualization and operator monitoring. It combines a 5.7-inch TFT color touch display with 320 x 240 pixel resolution and 65,536 colors. The panel operates on Microsoft Windows CE 5.0 and is designed for installation in industrial control cabinets, with an IP65-rated front panel and IP20-rated rear housing.

A replacement panel uses an integrated RJ45 Ethernet interface, an RS422/RS485 interface via Sub-D connector or a USB Type-A interface for connection and project transfer. The Ethernet interface supports PROFINET, Modbus TCP and Ethernet, while the serial interface supports MPI and PROFIBUS-DP. Commissioning a spare requires SIMATIC WinCC flexible 2008 Compact or higher, transfer of the HMI project and matching network or station settings. The 2 MB non-volatile Flash configuration memory stores the project, while integrated retentive memory preserves operational data.

For troubleshooting, the MP 177 provides a system diagnostic screen, WinCC flexible runtime diagnostics, system error messages on the HMI screen and online connection monitoring through WinCC flexible. During replacement commissioning, check the 24 V DC supply, the selected Ethernet or serial connection and the configured network or station settings before testing the transferred project. The 6AV6642-0EA01-3AX0 is discontinued, with a Siemens delivery stop effective October 1, 2014, making tested spare and repair options relevant for existing SIMATIC HMI installations.

Technical Specifications

ManufacturerSiemens
Part number6AV6642-0EA01-3AX0
Model/typeMulti Panel : MP177 6 Touch
Component typeHMI multi panel
Product familySIMATIC HMI
Display5.7-inch TFT color display with touch operation
Display resolution320 x 240 pixels
Display colors65,536 colors
Operating systemMicrosoft Windows CE 5.0
Supply voltage24 V DC
Rated power consumption12 W
Configuration memory2 MB Flash
Retentive memoryIntegrated
Ethernet interfaceIntegrated RJ45 Ethernet interface
Serial interfaceRS422/RS485 via Sub-D connector
USB interfaceUSB Type-A
Supported fieldbus protocolsMPI and PROFIBUS-DP
Supported Ethernet protocolsPROFINET, Modbus TCP and Ethernet
Engineering softwareSIMATIC WinCC flexible 2008 Compact or higher
Software PLC supportWinAC MP
Front protection ratingIP65; NEMA 4, NEMA 4X and NEMA 12 when installed
Rear protection ratingIP20
Lifecycle statusDiscontinued; delivery stop effective October 1, 2014

Programming and Configuration

The MP 177 is configured with SIMATIC WinCC flexible 2008 Compact or higher. Project transfer can be performed through the integrated Ethernet interface or the MPI connection, using the applicable Ethernet or serial connection method.

Before commissioning a spare, transfer the HMI project and align the network or station settings with the existing installation. The 2 MB non-volatile Flash configuration memory stores the HMI project, while integrated retentive memory preserves operational data. WinAC MP software PLC support is also available for the MP 177 hardware architecture.

Communication and System Integration

The panel provides an integrated RJ45 Ethernet interface for PROFINET, Modbus TCP and standard Ethernet networking. This connection supports communication with Ethernet-based systems and can be used for project transfer and commissioning.

An RS422/RS485 interface via Sub-D connector supports MPI and PROFIBUS-DP communication with existing fieldbus architectures. The USB Type-A interface provides an additional connection on the HMI. Replacement checks should confirm that the installed connection type, protocol and network or station settings match the machine configuration.

Diagnostics and Status Indication

The MP 177 provides a system diagnostic screen, WinCC flexible runtime diagnostics and system error messages displayed on the HMI screen. Online connection monitoring through WinCC flexible helps assess the communication status during commissioning and troubleshooting.

For a replacement panel, first check the 24 V DC supply, the selected Ethernet or RS422/RS485 connection and the configured network or station settings. Then verify that the transferred WinCC flexible project is running correctly on the panel.

Replacement and Spare Part Considerations

The exact replacement reference is Siemens 6AV6642-0EA01-3AX0, model/type Multi Panel : MP177 6 Touch. Compatibility checks should include the part number, the 5.7-inch touch display, the required Ethernet or RS422/RS485 interface and the communication protocol used by the machine. The front panel is rated IP65, while the rear housing is IP20; installation must preserve the required enclosure protection.

A spare panel requires project transfer and configuration before it can operate in the machine. Use SIMATIC WinCC flexible 2008 Compact or higher and match the existing network or station settings. The discontinued status and Siemens delivery stop effective October 1, 2014 make a tested exchange unit or repair option relevant when maintaining an existing MP 177 installation.

Frequently Asked Questions

What is the Siemens 6AV6642-0EA01-3AX0?

It is a Siemens SIMATIC MP 177 6 Touch HMI multi panel with a 5.7-inch TFT touch display, 320 x 240 pixel resolution and 65,536 colors.

Which software is required to configure the MP 177?

The panel requires SIMATIC WinCC flexible 2008 Compact or higher for configuration and project transfer.

Which communication protocols does this MP 177 support?

The integrated RS422/RS485 interface supports MPI and PROFIBUS-DP. The RJ45 Ethernet interface supports PROFINET, Modbus TCP and Ethernet.

What must be transferred when commissioning a replacement panel?

The HMI project must be transferred using Ethernet or MPI, and the network or station settings must match the existing installation.

How can the MP 177 be diagnosed during commissioning?

Use the system diagnostic screen, WinCC flexible runtime diagnostics, HMI system error messages and online connection monitoring through WinCC flexible.

Is the Siemens 6AV6642-0EA01-3AX0 discontinued?

Yes. The panel is discontinued, with a Siemens delivery stop effective October 1, 2014.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Siemens.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.