Siemens 3RW5236-6TC04 SIRIUS 171 A Soft Starter

Het item werd toegevoegd aan uw offerteaanvraag
Product Information
The Siemens 3RW5236-6TC04 is a SIRIUS 3RW52 general-performance soft starter for controlled starting and stopping of three-phase asynchronous motors. It handles a rated operating voltage of 200-480 V AC and a rated operational current of 171 A at 40 °C ambient temperature, with a 24 V AC/DC control supply. Screw terminals are provided for the main and control circuits. The integrated bypass contact system supports efficient running operation, while the thermistor input supports motor temperature monitoring and overload protection.
Replacement commissioning requires the motor, control supply, wiring and installed options to match the existing SIRIUS 3RW52 installation. Starting voltage can be adjusted from 30% to 100%, startup ramp time from 0-20 seconds and starting current limit from 130% to 700%; the stopping voltage is fixed at 50%. Optional plug-in communication modules provide PROFINET, PROFIBUS DP, Modbus TCP, Modbus RTU or EtherNet/IP connectivity, while the Standard HMI 3RW5980-0HS00 and High Feature HMI 3RW5980-0HF00 support local operation. SIRIUS Soft Starter ES software can be used for configuration and commissioning, and the High Feature HMI also supports diagnostics and parameter transfer.
For troubleshooting, the RN / ERROR / STATE indicators on the main unit and optional HMI modules show device status, overload, bypass state or a system trip. The motor thermistor input supports overload monitoring and trip evaluation, while remote reset is available via the control terminals. Check the screw-terminal connections, 24 V AC/DC control supply, motor thermistor circuit and any installed communication or HMI module during replacement commissioning. The 3RW5236-6TC04 is rated for motors up to 45 kW inline at 230 V, 90 kW inline at 400 V, 90 kW inside-delta at 230 V and 160 kW inside-delta at 400 V.
Technical Specifications
| Manufacturer | Siemens |
| Part number | 3RW5236-6TC04 |
| Model/type | SIRIUS 3RW52 general-performance soft starter |
| Product family | SIRIUS 3RW52 |
| Component type | Three-phase motor soft starter |
| Rated operating voltage | 200-480 V AC |
| Rated operational current | 171 A at 40 °C ambient |
| Control supply voltage | 24 V AC/DC |
| Controlled phases | 3 phases |
| Rated motor power, inline at 230 V | 45 kW |
| Rated motor power, inline at 400 V | 90 kW |
| Rated motor power, inside-delta at 230 V | 90 kW |
| Rated motor power, inside-delta at 400 V | 160 kW |
| Starting voltage range | 30-100% of rated voltage |
| Stopping voltage | 50% of rated voltage, non-adjustable |
| Startup ramp time | 0-20 s |
| Starting current limit | 130-700% of rated current |
| Main and control connections | Screw terminals |
| Motor protection input | Integrated thermistor input |
| Bypass system | Integrated bypass contact system |
| Degree of protection | IP00; IP20 with terminal covers installed |
| Optional communication interfaces | PROFINET, PROFIBUS DP, Modbus TCP, Modbus RTU, EtherNet/IP |
| Communication module requirement | Optional plug-in module required; communication is not built in |
| Product lifecycle status | Active |
Programming and Configuration
SIRIUS Soft Starter ES software supports configuration, commissioning and diagnostics of the 3RW5236-6TC04. Configuration can also be performed through the Standard HMI 3RW5980-0HS00 or the High Feature HMI 3RW5980-0HF00.
The High Feature HMI supports parameter transfer, which can simplify preparation of a spare unit. Commissioning includes matching the starting voltage, startup ramp time and starting current limit to the motor and driven load. The 24 V AC/DC control supply, screw-terminal wiring and integrated thermistor circuit must also be connected correctly.
Communication and System Integration
The 3RW5236-6TC04 supports optional network integration through plug-in Siemens communication modules. Available interfaces include PROFINET, PROFIBUS DP, Modbus TCP, Modbus RTU and EtherNet/IP.
Communication is provided through an optional plug-in module rather than through an integrated interface. Available modules include 3RW5980-0CS00 for PROFINET, 3RW5980-0CP00 for PROFIBUS, 3RW5980-0CT00 for Modbus TCP, 3RW5980-0CR00 for Modbus RTU and 3RW5980-0CE00 for EtherNet/IP.
Diagnostics and Status Indication
The RN / ERROR / STATE indicators on the main unit and optional HMI modules show device status, overload, bypass state or a system trip. The High Feature HMI 3RW5980-0HF00 supports configuration, monitoring and diagnostics.
SIRIUS Soft Starter ES software can provide diagnostics through an optional fieldbus communication module. The integrated motor thermistor input supports overload monitoring and trip evaluation, and the control terminals provide a remote reset function.
Status LED Indicators
| LED | Color/Status | Meaning |
|---|---|---|
| RN / ERROR / STATE | Documented indicators on the main unit and optional HMI modules show device status, overload, bypass state, or system trip. |
Replacement and Spare Part Considerations
When selecting a replacement, match the complete part number 3RW5236-6TC04, the 200-480 V AC rated operating voltage, the 171 A rated operational current, the 24 V AC/DC control supply and the screw-terminal connection style. Also check whether the original unit uses an HMI or an optional communication module.
A spare unit may require configuration before it can return to service. Transfer or restore the starting voltage, startup ramp time and starting current limit, then check the motor connection, thermistor circuit, control wiring and any network module. The High Feature HMI 3RW5980-0HF00 supports parameter transfer, while SIRIUS Soft Starter ES supports configuration and commissioning.
Frequently Asked Questions
What is the rated current of the Siemens 3RW5236-6TC04?
The rated operational current is 171 A at 40 °C ambient temperature.
What control supply does the 3RW5236-6TC04 require?
The soft starter uses a 24 V AC/DC control supply.
Which communication networks can be used with this soft starter?
Optional plug-in modules support PROFINET, PROFIBUS DP, Modbus TCP, Modbus RTU and EtherNet/IP.
Which software is used to configure the Siemens 3RW5236-6TC04?
SIRIUS Soft Starter ES supports configuration, commissioning and diagnostics. The High Feature HMI 3RW5980-0HF00 also supports configuration, diagnostics and parameter transfer.
What should be checked when commissioning a replacement unit?
Match the part number, voltage, current, control supply, screw-terminal wiring and installed options. Check the motor thermistor circuit, control wiring, communication module and configured starting parameters.
Take advantage of our exchange formula
A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.
Play it safe with our warranty conditions
Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.
Data backup and recovery
Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.
Specific firmware and hardware versions
If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.
Disclaimer:
We are not an authorised distributor of Siemens.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.