Schneider Electric ATS480C17Y Altivar ATS480 Soft Starter

New 
On request
Refurbished   
On request
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: Altivar Soft Starter ATS480 | Series: ATS480

The Schneider Electric ATS480C17Y is an Altivar ATS480 motor soft starter for controlled acceleration and deceleration of three-phase asynchronous motors. It supports a 208–690 V AC main supply and provides a normal-duty rated current of 170 A or a heavy-duty rated current of 140 A, with a 110–230 V AC control supply. The IP00 unit is intended for installation inside an appropriately protected electrical enclosure and supports motor-control applications including pumps, fans, compressors, conveyors and process machinery.

For machine integration, the ATS480C17Y provides four digital inputs, two programmable open-collector digital outputs, three relay outputs, one PTC or Pt100 temperature-probe input and one configurable 0–20 mA or 0–10 V analog output. Built-in two-wire RS-485 communication uses an RJ45 connector and Modbus RTU in slave mode, with addresses 0–227 and communication speeds from 1200–256000 bit/s. Optional communication modules support PROFIBUS DP V1, Modbus TCP, EtherNet/IP and CANopen. When replacing a unit, check the motor rating, main and control supply, installed communication module and I/O wiring, then restore the required parameters from the internal non-volatile memory or configure the second motor parameter set as required.

The soft starter provides integrated monitoring for line and motor phase loss, thermal conditions of the starter and motor, current overload and underload, and locked-rotor conditions. Parameter backup and restoration through internal non-volatile memory supports replacement commissioning and helps retain the configuration required by the machine. Before returning the motor system to service, verify the supply connections, control wiring, communication connection, motor parameters and the selected normal-duty or heavy-duty operating mode.

Technical Specifications

ManufacturerSchneider Electric
Part numberATS480C17Y
Model/typeAltivar ATS480 soft starter
Component typeMotor soft starter
Product familyAltivar Soft Starter ATS480
Normal-duty rated current170 A at 40 °C
Heavy-duty rated current140 A at 40 °C
Main supply voltage208–690 V AC, 3-phase
Supply frequency50/60 Hz
Control supply voltage110–230 V AC
Normal-duty rated power at 230 V45 kW
Normal-duty rated power at 400 V90 kW
Heavy-duty rated power at 400 V75 kW
Normal-duty rated power at 690 V160 kW
Digital inputs4: STOP, RUN, DI3 and DI4
Digital outputs2 programmable open-collector outputs, DQ1 and DQ2; maximum 30 V
Relay outputs3 relay outputs
Analog input1 AI1/PTC input for PTC or Pt100 temperature probe
Analog output1 configurable AQ1 output, 0–20 mA or 0–10 V
Built-in communication interface2-wire RS-485 via RJ45
RS-485 communication speed1200–256000 bit/s
Built-in protocolModbus RTU, slave mode, addresses 0–227
Optional communication protocolsPROFIBUS DP V1, Modbus TCP, EtherNet/IP and CANopen via option modules
Protection ratingIP00
Parameter storageInternal non-volatile memory with backup, restore and second motor parameter set support

Communication and System Integration

The ATS480C17Y has a built-in two-wire RS-485 interface with an RJ45 connector. Modbus RTU operates in slave mode with addresses 0–227 and selectable communication speeds from 1200–256000 bit/s, supporting PLC and control-system integration.

Network options depend on the installed communication module. PROFIBUS DP V1, Modbus TCP, EtherNet/IP and CANopen are supported through optional modules, so the module type and associated network connection must match the machine configuration when a replacement soft starter is prepared.

Diagnostics and Status Indication

Integrated monitoring identifies line and motor phase loss, thermal conditions affecting the soft starter and motor, current overload or underload, and locked-rotor conditions. These functions support troubleshooting of motor-starting and motor-running problems within the application.

For replacement commissioning, check the main supply, 110–230 V AC control supply, motor and control wiring, RS-485 or optional network connection, and the configured motor parameters. Internal non-volatile memory supports parameter backup and restoration, including a second motor parameter set.

Replacement and Spare Part Considerations

A replacement ATS480C17Y should be matched by exact part number, motor current duty, main supply range, control supply voltage and installed communication option. Confirm whether the machine uses the 170 A normal-duty or 140 A heavy-duty rating and check the 230 V, 400 V or 690 V motor-power requirement.

Before commissioning the spare, compare the digital and relay output wiring, temperature-probe connection, analog output selection and network connection with the existing installation. Restore the stored parameters or configure the required second motor parameter set, then verify the motor, control and communication functions before returning the equipment to operation.

Frequently Asked Questions

What is the rated current of the Schneider Electric ATS480C17Y?

The ATS480C17Y is rated at 170 A in normal-duty applications and 140 A in heavy-duty service, both at 40 °C.

What motor supply voltage does the ATS480C17Y accept?

It accepts a 208–690 V AC, three-phase main supply and uses a 110–230 V AC control supply.

Which communication protocol is built into the ATS480C17Y?

The built-in two-wire RS-485 interface uses Modbus RTU in slave mode, with addresses 0–227 and speeds from 1200–256000 bit/s.

Can the ATS480C17Y connect to PROFIBUS or Ethernet networks?

PROFIBUS DP V1, Modbus TCP, EtherNet/IP and CANopen are supported through optional communication modules. The installed module must match the machine network.

What should be checked when commissioning an ATS480C17Y replacement?

Check the exact part number, duty rating, main and control supply, communication module, I/O wiring, motor parameters and network connection. Parameters can be backed up and restored through internal non-volatile memory.

Which motor conditions can the ATS480C17Y monitor?

The soft starter monitors line and motor phase loss, starter and motor thermal conditions, current overload and underload, and locked-rotor conditions.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Schneider Electric.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.