Product Information

Product Family: SINAMICS S120

The Siemens 6SL3120-1TE26-0AA3 is a SINAMICS S120 Single Motor Module for coordinated motor control in modular multi-axis automation systems. It uses the compact Booksize format with internal air cooling and connects to a common 600 V DC link. The module provides 400 V three-phase motor output, a 60 A rated output current, a 113 A maximum output current and 32 kW rated power. SINAMICS S120 systems use a central Control Unit, such as the CU320-2, to coordinate multiple motor modules.

Replacement commissioning requires more than matching the Siemens part number. The spare must be connected to the 600 V DC link busbar, motor power wiring and the existing DRIVE-CLiQ network through its RJ45 connections. DRIVE-CLiQ supports drive communication, feedback integration, topology management and electronic rating-plate detection. STARTER and SINAMICS Startdrive within TIA Portal support commissioning, parameterization and diagnostics. Before installation, verify the Booksize format, cooling arrangement, output-current rating and DRIVE-CLiQ topology. ABC Industrial Parts can support preparation of a replacement or exchange unit for the existing system configuration.

The SINAMICS S120 system indicates operating status through the RDY LED and provides diagnostic functions through the Control Unit alarm and fault buffer, DRIVE-CLiQ topology diagnosis, STARTER, SINAMICS Startdrive within TIA Portal and the central Control Unit web server. A solid green RDY indication means the drive is ready for operation; red indicates a non-clearing hardware or internal fault requiring repair or replacement, while orange indicates initialization. Check the DC link, auxiliary supply, motor connections and DRIVE-CLiQ wiring during troubleshooting, then use the connected Control Unit diagnostic functions to assess the system state.

Technical Specifications

ManufacturerSiemens
Part number6SL3120-1TE26-0AA3
Model/typeSINAMICS S120 Single Motor Module
Product familySINAMICS S120
Component typeSingle motor module
DC link voltage600 V DC
DC link voltage range510-720 V DC
Output voltage400 V AC, 3-phase
Rated output current60 A
Maximum output current113 A
DC link current72 A
Rated power32 kW
Auxiliary supply24 V DC
Auxiliary supply current1.05 A
Output frequency range0-650 Hz
Standard switching frequency4 kHz
Maximum switching frequency16 kHz
Mounting formatBooksize
Cooling methodInternal air cooling
Sound pressure level65 dB
Drive communication interfaceDRIVE-CLiQ via RJ45
System busDRIVE-CLiQ
Power input interface600 V DC link busbar connection
Safety functionsExtended Safety Integrated support

Programming and Configuration

The Siemens SINAMICS S120 Single Motor Module is commissioned as part of a central-control architecture. Siemens STARTER and SINAMICS Startdrive within TIA Portal support engineering, commissioning, parameterization and diagnostics for the drive system.

During replacement, the central Control Unit uses DRIVE-CLiQ topology management and electronic rating-plate detection to identify the connected hardware. The existing drive configuration, feedback integration and system topology must be checked before the machine is returned to operation.

The replacement process includes connecting the module to the common DC link, motor power circuit and DRIVE-CLiQ network, followed by commissioning checks in the selected Siemens engineering environment.

Communication and System Integration

Communication with the SINAMICS S120 system is provided through DRIVE-CLiQ via RJ45 connections. DRIVE-CLiQ handles drive communication, feedback integration and topology management between the motor module, Control Unit and associated feedback devices.

The module is designed for SINAMICS S120 common DC link architecture and operates with a central Control Unit such as the CU320-2. Multiple motor modules can be integrated into a shared DC link system for coordinated multi-axis motion control.

The power interface is a 600 V DC link busbar connection, while the motor side provides 400 V AC, 3-phase output. Correct DRIVE-CLiQ topology and compatible feedback connections are required for system integration and replacement commissioning.

Diagnostics and Status Indication

SINAMICS S120 diagnostic functions include DRIVE-CLiQ topology diagnosis, the SINAMICS Control Unit diagnostic alarm and fault buffer, Siemens STARTER, SINAMICS Startdrive within TIA Portal and the central Control Unit web server.

The RDY LED provides a direct status indication on the SINAMICS S120 system. A solid green indication means the drive is ready for operation. Red indicates a non-clearing hardware or internal fault requiring repair or replacement, while orange indicates initialization.

Status LED Indicators

LEDColor/StatusMeaning
RDYGreen, red, orange - Solid green; red; orange during initializationSolid green indicates the drive is ready for operation. Red indicates a non-clearing hardware or internal fault requiring repair or replacement. Orange indicates initialization.

Replacement and Spare Part Considerations

For a compatible spare, match the exact Siemens part number 6SL3120-1TE26-0AA3 and confirm the SINAMICS S120 Booksize format, 60 A rated output current, 32 kW rated power and 600 V DC link connection. The 400 V three-phase motor output and 113 A maximum output current should also correspond to the installed motor application.

A replacement module must be integrated into the existing common DC link, motor power circuit and DRIVE-CLiQ topology. Check the RJ45 DRIVE-CLiQ connections, feedback integration, auxiliary 24 V DC supply and cooling arrangement before commissioning.

A red RDY indication identifies a non-clearing hardware or internal fault for which repair or a tested exchange unit may be more appropriate than repeated field resets. STARTER or SINAMICS Startdrive can then be used to complete topology, parameterization and diagnostic checks.

Frequently Asked Questions

What is the Siemens 6SL3120-1TE26-0AA3?

It is a SINAMICS S120 Single Motor Module with 60 A rated output current, 32 kW rated power, 600 V DC link input and 400 V three-phase motor output.

Which communication interface does this SINAMICS S120 motor module use?

The module uses Siemens DRIVE-CLiQ via RJ45 connections for drive communication, feedback integration and topology management.

Which software is used to commission the 6SL3120-1TE26-0AA3?

Siemens STARTER and SINAMICS Startdrive within TIA Portal support engineering, commissioning, parameterization and diagnostics.

What must be checked before installing a replacement motor module?

Check the exact part number, Booksize format, rated output current, rated power, DC link connection, motor wiring, auxiliary 24 V DC supply, cooling arrangement and DRIVE-CLiQ topology.

What does a red RDY LED indicate?

For the SINAMICS S120 system, red RDY indicates a non-clearing hardware or internal fault requiring repair or replacement.

What does a solid green RDY LED indicate?

A solid green RDY indication means that the drive is ready for operation.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Siemens.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.