Allen-Bradley 2198-H015-ERS2 Bulletin 2198 12,5Apk Servo Drive

Het item werd toegevoegd aan uw offerteaanvraag
Product Information
The Allen-Bradley 2198-H015-ERS2 is a Bulletin 2198 12,5Apk servo drive from the Kinetix 5500 family. This Frame 2 servo drive provides coordinated motion control for packaging and converting machinery, material handling and assembly equipment, robotics, and other discrete manufacturing machines. It delivers up to 12.5 A 0-peak peak output current, 7.1 A RMS continuous output current, and integrated Safe Torque-Off over EtherNet/IP.
A replacement connects to the machine through EtherNet/IP using CIP Motion, with two RJ45 Ethernet ports for linear, star, or Device Level Ring topologies. A dedicated 2-pin MF connector provides the motor feedback interface. Commissioning is performed in Studio 5000 Logix Designer with CompactLogix 5370, GuardLogix 5570, or ControlLogix controller environments. Before a spare is put into service, match the 2198-H015-ERS2 safety profile, compatible firmware, Studio 5000 Add-On Profile, and the required standalone or shared AC/DC bus arrangement. Zero-stack mounting and shared DC bus alignment also need to be correct where applicable.
Drive status and motion information can be assessed through Studio 5000 Logix Designer Axis Diagnostics, controller diagnostic registers, CIP Motion diagnostic attributes over EtherNet/IP, and integrated GuardLogix safety status monitoring. For troubleshooting, check the EtherNet/IP connection, controller diagnostics, safety status, motor feedback connection, and the configured bus arrangement against the machine setup. When an internal servo drive fault prevents normal operation, a repair or tested exchange unit can provide a practical route to restoring the machine.
Technical Specifications
| Manufacturer | Allen-Bradley |
| Part number | 2198-H015-ERS2 |
| Model/type | Bulletin 2198 12,5Apk Servo Drive |
| Component type | Servo drive |
| Product family | Kinetix 5500 |
| Frame size | Frame 2 |
| Input voltage range | 195-528 V AC, three-phase |
| Input frequency range | 47-63 Hz |
| Rated power, single-phase 230 V AC | 1 kW |
| Rated power, three-phase 230/240 V AC | 1.5 kW |
| Rated power, three-phase 480 V AC | 3.2 kW |
| Continuous output current | 7.1 A RMS |
| Continuous output current, 0-peak | 5 A |
| Peak output current | 17.7 A RMS |
| Peak output current, 0-peak | 12.5 A |
| Efficiency | 97% |
| Internal shunt power | 50 W |
| Short-circuit current rating | 200000 A RMS symmetrical |
| Network interface | Dual Ethernet ports with RJ45 connectors |
| Communication protocol | EtherNet/IP with CIP Motion and integrated safety |
| Supported network topologies | Linear, star, and Device Level Ring (DLR) |
| Motor feedback interface | Dedicated 2-pin MF connector |
| Velocity loop bandwidth | Up to 300 Hz |
| Current loop bandwidth | Up to 1000 Hz |
| DC bus configuration | Standalone, shared AC, shared DC, shared AC/DC, and shared AC/DC hybrid configurations |
| Safety function | Integrated Safe Torque-Off over EtherNet/IP |
| Configuration software | Studio 5000 Logix Designer |
Programming and Configuration
Configuration and commissioning use Studio 5000 Logix Designer. The drive integrates with CompactLogix 5370, GuardLogix 5570, and ControlLogix controller environments, allowing the motion setup to be handled within the controller-based machine configuration.
For a replacement, confirm that the new unit uses the 2198-H015-ERS2 safety profile, compatible firmware, and the required Studio 5000 Add-On Profile. The machine configuration must also reflect the installed standalone, shared AC, shared DC, shared AC/DC, or shared AC/DC hybrid bus arrangement.
Communication and System Integration
The 2198-H015-ERS2 communicates over EtherNet/IP and supports CIP Motion, drive monitoring, parameter configuration, and integrated safety. Two Ethernet ports with RJ45 connectors support linear, star, and Device Level Ring (DLR) network topologies.
A dedicated 2-pin MF connector provides the motor feedback interface. The Kinetix 5500 family supports standalone operation as well as shared AC, shared DC, shared AC/DC, and shared AC/DC hybrid configurations for coordinated multi-axis architectures.
Diagnostics and Status Indication
Diagnostic access is provided through Studio 5000 Logix Designer Axis Diagnostics, controller diagnostic registers, and CIP Motion diagnostic attributes over EtherNet/IP. These tools support assessment of drive and axis status within the controller-based motion system.
GuardLogix installations can also use integrated safety status monitoring. During troubleshooting, review the EtherNet/IP connection, controller diagnostic information, CIP Motion attributes, safety status, motor feedback connection, and the configured bus arrangement.
Replacement and Spare Part Considerations
Use the exact Allen-Bradley 2198-H015-ERS2 part number when matching a replacement. The safety profile, compatible firmware, Studio 5000 Add-On Profile, motor feedback connection, and EtherNet/IP integration all need to correspond with the existing machine configuration.
Check the installed power and bus architecture before commissioning the spare. Standalone, shared AC, shared DC, shared AC/DC, and shared AC/DC hybrid configurations are supported, while zero-stack mounting and shared DC bus alignment must be correct where applicable. A repair or tested exchange unit can be considered when an internal drive fault prevents the original unit from returning to service.
Frequently Asked Questions
What is the Allen-Bradley 2198-H015-ERS2?
It is a Frame 2 Kinetix 5500 servo drive with up to 12.5 A 0-peak peak output current, EtherNet/IP CIP Motion communication, and integrated Safe Torque-Off over EtherNet/IP.
Which software is used to configure the 2198-H015-ERS2?
Configuration and commissioning use Studio 5000 Logix Designer. The drive integrates with CompactLogix 5370, GuardLogix 5570, and ControlLogix controller environments.
Which network connections are available on this servo drive?
The drive has two Ethernet ports with RJ45 connectors and supports EtherNet/IP with CIP Motion. Linear, star, and Device Level Ring (DLR) topologies are supported.
What must be checked before commissioning a replacement drive?
Confirm the exact 2198-H015-ERS2 part number, safety profile, compatible firmware, Studio 5000 Add-On Profile, motor feedback connection, bus configuration, zero-stack mounting, and shared DC bus alignment where applicable.
How can the 2198-H015-ERS2 be diagnosed in a machine?
Use Studio 5000 Logix Designer Axis Diagnostics, controller diagnostic registers, CIP Motion diagnostic attributes over EtherNet/IP, and integrated GuardLogix safety status monitoring.
Take advantage of our exchange formula
A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.
Play it safe with our warranty conditions
Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.
Data backup and recovery
Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.
Specific firmware and hardware versions
If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.
Disclaimer:
We are not an authorised distributor of Allen-Bradley.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.