Siemens 6SE7016-0TP50-Z Masterdrive MC Frequency Inverter

Het item werd toegevoegd aan uw offerteaanvraag
Product Information
The Siemens 6SE7016-0TP50-Z is a SIMOVERT MASTERDRIVES MC Compact Plus frequency inverter for variable-speed motor control and high-dynamic positioning equipment. It provides 2.2 kW rated output power and 6.1 A rated output current from a 510-650 V DC link supply. The configured unit includes F01 Standard Technology Functions for positioning, synchronous operation and electronic cam functions, together with the G91, C43 and G42 options.
Replacement commissioning requires more than fitting the inverter into the cabinet. The DC link bus input, rated motor requirements, installed options and communication hardware must match the existing installation. Built-in USS supports control and parameterization, while PROFIBUS-DP is available through an optional CBP2 communication board. Parameters can be accessed with the PMU or Siemens DriveMonitor software, and the non-volatile internal EEPROM supports parameter upload, download and transfer to a compatible replacement with matching Z-options and compatible firmware.
The PMU 7-segment display shows operating status, parameter numbers, parameter values, alarms and fault codes including F001 and F006. DriveMonitor provides diagnostic tracing, while fault memory can be read through parameters r947 and r949 and status words through r001 and r002. When a fault points to internal pre-charge, control-board or EEPROM hardware, service or a tested exchange drive may be more practical than field-level troubleshooting; ABC Industrial Parts can support parameter recovery and replacement preparation for legacy MASTERDRIVES equipment.
Technical Specifications
| Manufacturer | Siemens |
| Part number | 6SE7016-0TP50-Z (Z=F01+G91+C43+G42) |
| Model/type | SIMOVERT MASTERDRIVES MC Compact Plus Inverter |
| Product family | SIMOVERT MASTERDRIVES |
| Component type | Frequency inverter |
| Rated output power | 2.2 kW |
| Rated output current | 6.1 A |
| DC link supply voltage | 510-650 V DC |
| Input type | DC link bus input |
| Control application | Variable-speed motor control and high-dynamic positioning |
| Built-in communication protocol | USS |
| Optional fieldbus protocol | PROFIBUS-DP via optional CBP2 communication board |
| Technology function | F01 Standard Technology Functions, including positioning, synchronous operation and electronic cam functions |
| Configured Z options | F01+G91+C43+G42 |
| Option slot C | Installed C43 option; communication or encoder function depending on configuration |
| Parameter storage | Non-volatile internal EEPROM with parameter upload and download support |
| Service and diagnostic interface | Serial interface for PMU and DriveMonitor |
| Product lifecycle status | Discontinued |
Programming and Configuration
The PMU provides local parameterization, status monitoring and access to parameter values. Siemens DriveMonitor supports parameterization, diagnostic tracing and the transfer of parameter sets for commissioning and service work.
The internal non-volatile EEPROM supports parameter retention, upload and download. A replacement drive can therefore receive transferred parameters when its Z-options and firmware are compatible with the existing installation.
Before commissioning, compare the installed F01, G91, C43 and G42 options, confirm the 510-650 V DC link architecture and transfer the applicable parameter set through the PMU or DriveMonitor.
Communication and System Integration
USS is available as the built-in serial communication interface for control and parameterization. This interface also supports connection to the PMU and DriveMonitor service environment.
PROFIBUS-DP connectivity is available through an optional CBP2 communication board. The installed communication board and the required protocol arrangement must match the existing MASTERDRIVES system before a replacement is commissioned.
The C43 option is installed on this configured unit and can provide a communication or encoder function depending on the configuration. Confirm the installed function when matching a spare drive.
Diagnostics and Status Indication
The PMU 7-segment display shows operating status, parameter numbers, parameter values, alarms and fault codes. DriveMonitor adds diagnostic trace functions for commissioning and service.
The fault memory buffer can be read through parameters r947 and r949, while status words are available through r001 and r002. For F001, F006 or related power-stage faults, check the DC link supply, motor wiring, load, braking circuit and cooling conditions as applicable to the displayed fault.
Status LED Indicators
| LED | Color/Status | Meaning |
|---|---|---|
| PMU 7-Segment Display | Displays operating and diagnostic information | Shows operating status, parameter numbers, parameter values, and fault or alarm codes such as F001 and F006 |
Replacement and Spare Part Considerations
For a like-for-like replacement, match Siemens part number 6SE7016-0TP50-Z, the 2.2 kW rating, 6.1 A output current and 510-650 V DC link supply. The replacement must also match the installed F01, G91, C43 and G42 options and the communication arrangement used by the machine.
Check whether the existing installation uses built-in USS, an optional CBP2 PROFIBUS-DP board or the C43 option. The C43 function may relate to communication or encoder use depending on the configuration, so the installed function must be identified before fitting a spare.
Transfer the parameter set with the PMU or DriveMonitor when the replacement firmware and option configuration are compatible. If the failed unit has an internal pre-charge, control-board or EEPROM fault, repair or a tested exchange unit can reduce the time required to restore the machine.
Error Codes & Fault Codes
The following error codes may be displayed during operation or diagnostics:
| Code | Name | Description | Possible Cause | Recommended Action |
|---|---|---|---|---|
| F001 | Overcurrent | Drive output current exceeds the allowable threshold. | Short circuit or ground fault at the output terminals, excessive motor load, acceleration ramp set too steeply, or incorrect motor parameters. | Check motor wiring for short circuits or earth faults, verify motor parameters, inspect the mechanical load, and increase acceleration time. |
| F002 | Pre-charging Fault | DC link pre-charging did not complete within the specified time limit. | DC link input voltage is too low, or the internal pre-charge circuit relay or resistor is defective. | Check that the DC link supply is 510-650 V DC. If the supply is correct, service or replace the unit because an internal pre-charge hardware fault may be present. |
| F006 | Undervoltage | DC link voltage fell below the minimum voltage threshold. | DC link supply failure, voltage dip, or loss of an upstream line phase. | Check the DC link supply voltage and the upstream main power source. |
| F008 | Overvoltage | DC link voltage exceeded the maximum allowable limit. | Regenerative motor energy during deceleration, a missing or defective brake resistor, or excessive supply voltage. | Check the DC link voltage, verify brake resistor operation and connections, and increase deceleration time. |
| F011 | Drive Overtemperature | Power-section heatsink temperature exceeded the maximum limit. | Cooling fan failure or blockage, excessive ambient temperature, or insufficient clearance around the heatsink. | Check cooling fan operation, clean ventilation grilles, and reduce cabinet ambient temperature. |
| F051 | EEPROM Fault | An internal EEPROM memory read or write error occurred. | Control-board hardware defect or power interruption during parameter writing. | Factory-reset the drive parameters and attempt a reload. If the fault persists, replace the control board or drive. |
Frequently Asked Questions
What is the Siemens 6SE7016-0TP50-Z used for?
It is a SIMOVERT MASTERDRIVES MC Compact Plus frequency inverter for variable-speed motor control and high-dynamic positioning. Its F01 Standard Technology Functions support positioning, synchronous operation and electronic cam functions.
What power supply does this MASTERDRIVES MC inverter require?
The inverter uses a 510-650 V DC link bus input. It is rated for 2.2 kW output power and 6.1 A output current.
Which communication interfaces are available?
USS is built in for control and parameterization. PROFIBUS-DP is available through an optional CBP2 communication board, and the C43 option may provide a communication or encoder function depending on the configuration.
How can parameters be transferred to a replacement drive?
Parameters can be accessed and transferred using the PMU or Siemens DriveMonitor software. The replacement must have compatible firmware and matching F01, G91, C43 and G42 options.
How are faults displayed and investigated?
The PMU 7-segment display shows fault and alarm codes such as F001 and F006. DriveMonitor provides diagnostic tracing, while the fault memory can be read through r947 and r949 and status words through r001 and r002.
What should be checked for an F001 overcurrent fault?
Check the motor wiring for short circuits or earth faults, verify the motor parameters, inspect the mechanical load and increase the acceleration time.
Take advantage of our exchange formula
A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.
Play it safe with our warranty conditions
Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.
Data backup and recovery
Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.
Specific firmware and hardware versions
If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.
Disclaimer:
We are not an authorised distributor of Siemens.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.