Siemens 6SL3210-1KE21-7AF1 SINAMICS G120C Frequency Inverter

Het item werd toegevoegd aan uw offerteaanvraag
Product Information
The Siemens 6SL3210-1KE21-7AF1 is a SINAMICS G120C frequency inverter for three-phase motor control in industrial automation systems. It accepts a 380-480 V AC, 3-phase supply at 47-63 Hz and provides a rated power of 7.5 kW for low-overload applications or 5.5 kW for high-overload applications. The FSB frame-size drive has an IP20, UL Open Type housing, an integrated Class A EMC filter and an integrated braking chopper. V/f characteristic control and sensorless vector control support different motor operating requirements.
A replacement drive connects to the machine through its RJ45 industrial Ethernet interface for PROFINET or EtherNet/IP and through screw and spring terminals for the control I/O. The terminal strip provides six digital inputs, two digital outputs, one analog input and one analog output. Commissioning and parameterization can be performed with TIA Portal with Startdrive, a SINAMICS BOP-2 or IOP-2 operator panel, or parameters transferred with a SINAMICS SD memory card. Parameters can also be retained in the internal non-volatile EEPROM, so the replacement requires the correct configuration and parameter set rather than a simple power-up exchange.
For troubleshooting, the front-faceplate status LEDs, online diagnostics in TIA Portal with Startdrive, diagnostic screens on the BOP-2 or IOP-2 and fieldbus diagnostic registers provide the main checks. The RDY LED indicates readiness, operation, faults or parameterizing activity, while the BF LED indicates a PROFINET or EtherNet/IP fieldbus communication fault. Initial checks should include the 380-480 V AC supply, the RJ45 network connection, control-terminal wiring, drive parameters and the selected operating mode before assessing the replacement or repair requirement.
Technical Specifications
| Manufacturer | Siemens |
| Part number | 6SL3210-1KE21-7AF1 |
| Model/type | SINAMICS G120C |
| Component type | Frequency inverter |
| Product family | SINAMICS |
| Input voltage | 380-480 V AC, 3-phase |
| Input voltage tolerance | 380 V -20% to 480 V +10% |
| Input frequency | 47-63 Hz |
| Rated power, low overload | 7.5 kW |
| Rated power, high overload | 5.5 kW |
| Low-overload capability | 150% for 3 s, 110% for 57 s, 100% for 240 s |
| High-overload capability | 200% for 3 s, 150% for 57 s, 100% for 240 s |
| Control modes | V/f characteristic control and sensorless vector control |
| Maximum output frequency, V/f control | 550 Hz |
| Maximum output frequency, sensorless vector control | 240 Hz |
| Switching frequency | 4 kHz default |
| Maximum switching frequency | 16 kHz with derating |
| Digital inputs | 6 |
| Digital outputs | 2 |
| Analog inputs | 1 |
| Analog outputs | 1 |
| Industrial Ethernet interface | PROFINET and EtherNet/IP |
| Fieldbus connector | RJ45 |
| Control I/O connection | Screw and spring terminals |
| EMC filter | Integrated Class A |
| Braking chopper | Integrated |
| Frame size | FSB |
| Protection rating | IP20, UL Open Type |
| Parameter storage | Non-volatile internal EEPROM with optional SD memory card support |
Programming and Configuration
TIA Portal with Startdrive supports commissioning, parameterization and online diagnostics for the Siemens SINAMICS G120C 6SL3210-1KE21-7AF1. Configuration can also be handled with SINAMICS BOP-2 and IOP-2 operator panels, allowing the replacement drive to be prepared with the required drive parameters and operating mode.
Parameters are stored in the internal non-volatile EEPROM or transferred with a SINAMICS SD memory card. During a replacement, the parameter set, V/f or sensorless vector control selection, motor configuration and machine I/O assignments must match the installed drive application before the unit is returned to service.
Communication and System Integration
The -7AF1 variant provides built-in PROFINET and EtherNet/IP communication through an RJ45 industrial Ethernet interface. This connection supports integration of the frequency inverter with the machine network and the associated PLC system.
Local control signals are connected through screw and spring terminals. The available control I/O comprises six digital inputs, two digital outputs, one analog input and one analog output for machine commands, interlocks and analog signals.
Diagnostics and Status Indication
Drive status and communication faults can be checked through the front-faceplate LEDs, online diagnostics in TIA Portal with Startdrive, diagnostic screens on SINAMICS BOP-2 or IOP-2 operator panels and fieldbus diagnostic registers. The RDY indication covers readiness, operation, fault status and parameterizing activity. The BF indication identifies a PROFINET or EtherNet/IP fieldbus communication fault.
Status LED Indicators
| LED | Color/Status | Meaning |
|---|---|---|
| RDY | Green and red - Green indicates ready/operating; red indicates fault/error; flashing indicates parameterizing/commissioning | Indicates drive readiness, operating condition, fault status, or commissioning activity |
| BF | Indicates a PROFINET or EtherNet/IP fieldbus communication fault |
Replacement and Spare Part Considerations
For a compatible Siemens SINAMICS G120C replacement, match part number 6SL3210-1KE21-7AF1 and the -7AF1 PROFINET/EtherNet/IP interface variant. The FSB frame size, 7.5 kW low-overload rating or 5.5 kW high-overload rating, control I/O arrangement and communication connection should correspond to the installed drive.
A spare unit needs the correct parameter set before operation. Parameters can be restored from the internal non-volatile EEPROM or transferred with a SINAMICS SD memory card, then checked through TIA Portal with Startdrive or a BOP-2 or IOP-2 operator panel. Verify the supply, RJ45 fieldbus connection, control-terminal wiring and machine configuration during commissioning.
Frequently Asked Questions
What is the Siemens 6SL3210-1KE21-7AF1?
It is a Siemens SINAMICS G120C frequency inverter for 380-480 V AC, 3-phase motor control, with a 7.5 kW low-overload rating and a 5.5 kW high-overload rating.
Which communication protocols does this SINAMICS G120C support?
The -7AF1 variant supports PROFINET and EtherNet/IP through its built-in RJ45 industrial Ethernet interface.
Which software and operator panels can be used for commissioning?
Commissioning, parameterization and diagnostics can be performed with TIA Portal with Startdrive, SINAMICS BOP-2 or SINAMICS IOP-2 operator panels.
How can parameters be transferred to a replacement drive?
Parameters can be retained in the internal non-volatile EEPROM or transferred using a SINAMICS SD memory card. The configuration should then be checked with TIA Portal with Startdrive or a compatible operator panel.
What does the BF LED indicate?
The BF LED indicates a PROFINET or EtherNet/IP fieldbus communication fault. Check the RJ45 fieldbus connection and the network diagnostics.
What does the RDY LED indicate?
Green indicates ready or operating, red indicates a fault or error, and flashing indicates parameterizing or commissioning activity.
Take advantage of our exchange formula
A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.
Play it safe with our warranty conditions
Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.
Data backup and recovery
Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.
Specific firmware and hardware versions
If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.
Disclaimer:
We are not an authorised distributor of Siemens.
Product photos are for illustration purposes only and may differ from the actual product delivered.