Danfoss 195N0031 VLT2807PS2B20STR1DBF10A00C0 Variable Frequency Drive

New 
On request
Refurbished   
5 available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: VLT 2800

The Danfoss 195N0031 is a VLT 2800 variable frequency drive for motor speed control in industrial automation equipment. Model VLT2807PS2B20STR1DBF10A00C0 is rated at 0.75 kW (1 HP) and uses a single-phase 200-240 V AC supply. Its compact IP20 bookstyle enclosure supports side-by-side mounting, while the integrated R1 RFI filter, dynamic brake chopper and factory-fitted PROFIBUS DP communication identify this drive for installations requiring compact construction and fieldbus integration. The drive provides V/f control and VVC+ Voltage Vector Control.

When installing a Danfoss 195N0031 replacement, match the 195N0031 part number, VLT2807PS2B20STR1DBF10A00C0 model designation, single-phase 200-240 V supply, PROFIBUS DP function and dynamic braking requirements. The drive has five digital inputs, two analog inputs, one digital output, one analog output and one relay output; two digital inputs can be configured for pulse operation. Parameters can be stored in non-volatile memory and transferred using the Danfoss LCP Control Panel or MCT 10 Setup Software, so a spare normally requires parameter transfer and commissioning before returning the machine to service. ABC Industrial Parts can support preparation of a replacement or exchange unit.

For troubleshooting, use the LCP Control Panel readout, the MCT 10 Setup Software, the LCP alarm and warning log buffer, and status word or fault-code registers over RS-485 or PROFIBUS DP. The WARNING / ALARM LED indicates a drive trip, internal hardware fault or operational warning condition, while the BUS / FIELDBUS STATUS LED indicates the status of the PROFIBUS DP fieldbus option. Check the drive status, parameter set, control wiring and fieldbus connection during commissioning. The VLT 2800 family is discontinued, making repair and tested replacement relevant for existing machinery.

Technical Specifications

ManufacturerDanfoss
Part number195N0031
Model/typeVLT2807PS2B20STR1DBF10A00C0
Product familyVLT 2800
Component typeVariable Frequency Drive
Rated output power0.75 kW
Rated output power1 HP
Supply voltage200-240 V AC
Input phases1
Rated input current10.6 A
Rated output current4.2 A
Control methodV/f control and VVC+ Voltage Vector Control
Digital inputs5
Analog inputs2
Digital outputs1
Analog outputs1
Relay outputs1
Pulse inputs2 configurable digital inputs
Dynamic brake chopperIntegrated
RFI filterR1
Serial interfaceRS-485
Fieldbus protocolPROFIBUS DP
PROFIBUS DP data rate3 Mbit/s
Serial protocolModbus RTU
Enclosure ratingIP20 bookstyle enclosure
Mounting arrangementSide-by-side mounting
Lifecycle statusDiscontinued

Programming and Configuration

Parameter sets for the VLT 2800 drive can be stored in non-volatile memory. A replacement can be configured through the Danfoss LCP Control Panel or MCT 10 Setup Software, allowing the installed parameter set to be transferred before commissioning.

Before starting the replacement, compare the existing drive and spare by part number, model designation, supply class, PROFIBUS DP function and dynamic braking requirements. Restore or transfer the parameter set, then check the five digital inputs, two analog inputs, configurable pulse inputs, outputs and relay interface against the machine wiring.

Communication and System Integration

The Danfoss 195N0031 provides an integrated RS-485 serial interface and supports Modbus RTU applications through the series RS-485 interface, subject to the applicable configuration. The interface can be used for serial control and status exchange with compatible automation equipment.

Factory-fitted PROFIBUS DP communication supports integration into PROFIBUS DP control networks at up to 3 Mbit/s. During a replacement, verify that the installed drive has the required PROFIBUS DP function and that the fieldbus connection and configured drive parameters match the machine system.

Diagnostics and Status Indication

Drive status and operating information can be checked through the LCP Control Panel readout or MCT 10 Setup Software. The LCP panel provides an alarm and warning log buffer, while status word and fault-code registers can be read over RS-485 or PROFIBUS DP.

Use the front-panel indications and communication diagnostics to distinguish a drive trip, internal hardware fault, operational warning or PROFIBUS DP communication condition. During commissioning, check the parameter transfer, control connections and fieldbus connection before returning the replacement drive to operation.

Status LED Indicators

LEDColor/StatusMeaning
WARNING / ALARM LEDFlashing or illuminatedIndicates a drive trip, internal hardware fault, or operational warning condition.
BUS / FIELDBUS STATUS LEDIndicates the communication status of the PROFIBUS DP fieldbus option.

Replacement and Spare Part Considerations

For a compatible Danfoss VLT 2800 replacement, match the exact 195N0031 part number and VLT2807PS2B20STR1DBF10A00C0 model designation. Also confirm the single-phase 200-240 V AC supply, 0.75 kW (1 HP) rating, 4.2 A rated output current, PROFIBUS DP communication, IP20 bookstyle enclosure and integrated dynamic brake chopper.

A spare drive requires configuration work before it can control the machine. Transfer the parameter set with the LCP Control Panel or MCT 10 Setup Software, then verify the control wiring, pulse-input assignments, RS-485 or PROFIBUS DP connection and dynamic braking arrangement. A tested exchange unit or repair can be a practical route for an installed VLT 2800 system because the product family is discontinued.

Frequently Asked Questions

What is the Danfoss 195N0031?

The Danfoss 195N0031 is a VLT 2800 variable frequency drive, model VLT2807PS2B20STR1DBF10A00C0, rated at 0.75 kW (1 HP) for a single-phase 200-240 V AC supply.

Does the Danfoss 195N0031 include PROFIBUS DP?

Yes. The drive has factory-fitted PROFIBUS DP communication with a data rate of up to 3 Mbit/s.

Which software can be used to configure this VLT 2800 drive?

Parameters can be transferred using the Danfoss LCP Control Panel or MCT 10 Setup Software. The drive stores parameter sets in non-volatile memory.

What should be checked before installing a replacement 195N0031?

Match the 195N0031 part number and VLT2807PS2B20STR1DBF10A00C0 model designation, then verify the single-phase 200-240 V supply, PROFIBUS DP function, dynamic brake requirements, control wiring and parameter set.

How can the drive status be diagnosed?

Use the LCP Control Panel readout, MCT 10 Setup Software, the LCP alarm and warning log buffer, or status word and fault-code registers over RS-485 or PROFIBUS DP. The WARNING / ALARM LED indicates a trip, internal hardware fault or operational warning.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Danfoss.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.